Quincy Compressor Startup Checklist

Customer & Unit Info
 Customer:   S/O No.:  
 Unit Model:   Serial #:   
 Lube Type:  Quin-Syn Plus  Quin-Syn PG  Quin-Syn FG  Other:

Startup Checklist
   Review instruction manual
   Removing shipping bolts per instruction book
   Check electrical connections, unit grounded, protected against short circuits
   Check starter to control panel interconnect (external starter)
   Check control panel transformer connections & jumpers
   Check & verify setting of motor overload relay and fan circuit breaker
   Check all control panel electrical connections for tightness
   Check all shut down switch settings and adjust for specifications
   Check to ensure all safety Shields are in place
   Check fluid drain plugs for tightness and leakage
   Check fluid level in tank and top up if necessary (DO NOT MIX FLUIDS)
   Pour 1 qt of fluid into inlet (DO NOT MIX FLUIDS)
   Check for correct condensate drain line installation (open drain)
   Check cooling water connections (solenoid, strainer)
   Check air system piping (receiver, condensate collection)
   Check room for proper ventilation (see product data)
   Turn on power 
   Jog the compressor and verify correct drive motor and cooling fan motor rotation
   Start unit and run unloaded for a few minutes
   Stop unit & recheck fluid level
   Repair any oil, air or water leaks as required
   Restart and load compressor
   Adjust pressure switch for customer conditions
   Adjust cooling water flows
   Allow unit to warm, measure and record all temperature, pressures
   Instruct customer on unit operation
   Instruct customer on preventive main. sched. (Daily, 4000 hrs, 8000 hrs, etc.)
 Job Notes:
 
 Customer Signature:     Date:  
 Technician Signature:   Date: