Kaishan Compressor Quick Start Guide

   Check machine room conditions (See instruction manual) 
   Piping Check (See instruction manual) 
   Check electrical (Reference local electrical code & operating instructions) 
   Check for transport damage 
   Remove RED transport braces 
   Ensure main discharge valve is open 
   Check oil level(KCA oil is clear) 
   Turn coupling or pulley by hand both directions 
   Check incoming electrical for proper voltage to match unit 
   Check settings in controller: 
  - Load pressure settings
  - Unload pressure settings
  - Main motor & fan motor protection settings
  - Maxim & minimum voltage settings
  - Drive target pressure for VSD units
   Check to ensure data in controller matches measured data (adjust if necessary): 
  - Pressure readings
  - Temperature readings
  - Voltage readings
  - Current readings
   Visually check rotation matches directional arrow 
   Start unit, throttle discharge valve to hold a minimum 87 PSI to reduce oil carry over 
   After MAX PSI is reached, shutdown unit and check for leaks with soapy water 
   Run compressor until it reaches operating temperature
  (150F or higher but ensure temp reaches a stopping point below 200F) 
   Check air treatment for proper function, even if the air treatment is existing equipment: 
  - Dryer
  - Receiver
  - Filtration
  - Drains
   For water cooled units: 
  - Check water supply is minimum 30PSI
  - Check that incoming water and discharge water are maintaining temperatures
   Ensure pressure settings are correct 
   Ensure CT’s and Voltage are calibrated 
   Set the target pressure in the MOTOR VSD settings for VSD units 
   Adjust the modulation control valve for fixed speed units 
   Set motor and fan motor “Rated Current”: 
  - FLA X 1.1 for main motor
  - FLA for fan motor
   Fill out commissioning form 

 Remember that if pressure adjustments are made in the controller changing the
 target pressure in the MOTOR VSD settings are required for VSD units.

 Remember that if pressure adjustments are made in the controller adjusting the
 modulation control valve maybe required.